Metal device: effective maintenance of the power head

The power head is also known as the power tool holder and is mounted on the power turret. As industrial processes become more complex and complex for machine workpiece requirements. The emergence of the power head brings great convenience to the processing of high-precision parts. The power head is different from daily necessities and has the advantages of high precision, stable performance and good rigidity. The following is a small series for everyone to talk about the effective maintenance of the power head.

The power head is widely used in various industries, which not only brings huge economic benefits, but also is deeply favored and loved by new and old users. The price of the power head is relatively high. So, how should we extend the service life of the power head to create greater value for us?

Precautions before using the power head

1. For the first time, the power head needs to be first run-in. It is best to idle for one hour, and the no-load speed is 70% of the maximum speed.

2. The coolant must be filtered before it can be put into use. Unfiltered coolant may cause damage to parts. For example, the internal parts and oil seal of the power tool holder may not be used due to excessive wear, which may affect the production efficiency. Do not forget to turn on the cooling before use. The liquid is turned on, which is also to reduce the wear of the oil seal and the parts, so pay special attention.

3, followed by the problem of the knife seat, in the work to rotate within the limited speed, not overspeed, while the water pressure is also limited, can not exceed that limit, to avoid accidents.

4. Check the standby condition of each component before use, such as whether the water spray is blocked or not, and the water supply should not be overheated. When closing the external water, just tighten it with screws.

Effective maintenance of the power head

1. Appearance Maintenance After the daily work is completed, it is necessary to clean the iron scraps from the power head push rod, the drill chuck or the multi-axis drilling head, the cutter, etc., to keep the appearance of the power head clean and tidy.

2. After the lubrication and maintenance cleaning work is completed, remember to add the right amount of lubricant to the push rod and the drill chuck.

3. Maintenance of the motor Regularly clean the motor, check the position of the electrical device, and ensure that the electrical device is fixed, safe and tidy.

4. Maintenance of parts and components Regularly check the tightness of the screw bolts, the tension of the belt, whether the protective cover is intact, and whether the hydraulic damper leaks oil.

Maintenance precautions

When the power head fails, don't arbitrarily disassemble it, and then you must find the cause and then prescribe the right medicine. If you do not understand the reason, you must contact the manufacturer by telephone and carry out maintenance under the guidance of the manufacturer; if there is any repair, you can return to the factory or the agent for repair. And replace the "overage" parts of the power head and the damaged parts in time. Under normal use, the power head should be monitored and repaired once a year, and the power head should not be allowed to work.

PS: Storage considerations for non-use period

When the power head is not needed, be sure to clean it, apply anti-rust oil, and place it in a dry place.

The power head is the device used to make money. The longer the service life of the power head, the greater the economic benefits for us. Therefore, to extend the life of the power head must pay attention to the above points.

Global hardware network

Concerned about surprises

Label: Metal device: effective maintenance of the power head

Previous: The benefits of reasonable tool passivation Next: Change the oil, how to choose the right way to spend

Hospital Access Supervisory Control and Management System, short for HASCMS, is an intelligent access supervisory control and management system born with the development of hospitals, Internet of Things, Automatic Door technology. The system structure of Hospital Access Supervisory Control and Management System includes access control system, access supervisory control system and access management system. Functions of Hospital Access Supervisory Control and Management System are authority management, condition monitoring, big data function and space management. Hospital Access Supervisory Control and Management System is well applied to hospital automatic access doors, such as Hospital Main Entrance Door, hospital anti-radiation Hermetic Door , hospital operating room hermetic door, Hospital Access Partition Door, hospital emergency exit door, hospital administrative office door, hospital ICU ward door and hospital fire door.

Hospital Access Supervisory Control and Management System

Hospital Main Entrance Door,Anti-Radiation Hermetic Door For Hospital,Hospital Access Partition Door,Icu Ward Door For Hospital

Ningbo Gdoor System Control Technology Co., Ltd. , http://www.gdoor-cn.com

Posted on