How to clean geothermal heat pipe maintenance method

As the weather becomes colder and colder now, most families will install geothermal pipes at home to heat them. However, if the geothermal pipes are not maintained during use, they will make the ground warm. In the maintenance of warmth, how to clean the floor heating yourself, so that the floor heating longer life? Here we introduce: how to clean the geothermal pipe and geothermal pipe maintenance methods.

How to clean the geothermal pipe

How to clean geothermal pipes - importance of cleaning geothermal pipes

After the geothermal pipeline is used for a period of time, there will be a large amount of slime, bacteria and scale generated on the inner wall of the pipeline, which is attached to the inner wall of the pipeline and forms a blockage of the pipeline, resulting in poor circulation of the water flow and insufficient heat dissipation, which seriously affects the heating temperature and effect. Practice has shown that when the floor heating is in use, the inner wall of the geothermal pipe will increase 1mm of dirt each year, which will cause the temperature in the heating room to drop by 6°C. This not only affected the normal use of floor heating, but also caused a waste of energy, so cleaning geothermal pipes is imminent.

How to clean geothermal pipe - filter cleaning

Floor heating should be cleaned once a year before use. The specific method is as follows: First, close the inlet and outlet valves of the connecting pipe, then open the filter, filter and clean it, check whether the filter is broken and blocked. If it is damaged, it should be replaced with the same size of filter, according to the original can be installed. Geothermal pipe refers to a kind of pipe that is used as a carrier of circulating low-temperature hot water in floor heating. In the floor heating system, air may accumulate in the pipeline during the start of water supply or use, which will affect the heating effect. At this point, the manifold's purge valve can be opened and the gas can be vented in the same way as conventional heating. The water flow of each branch of the system can be adjusted by adjusting the ball valve on each branch and achieve the purpose of controlling the temperature of each part. However, adjustments should be made carefully so as not to affect other branches. The geothermal pipe laid under the ground is only about 3-100 px from the floor, and knocking and hitting the ground can easily damage the geothermal pipe. Therefore, the floor on which geothermal pipes are laid must not be knocked or hit to prevent damage to the geothermal pipes.

How to clean geothermal pipe - chemical agent soak cleaning

The chemicals are soaked and cleaned. This cleaning method can fully dissolve the slime adhered to the pipe wall. The high-quality food grade raw material used by it does not cause corrosion to the geothermal pipes and is thoroughly cleaned. The cleaning process is: open the hot and warm water inlet pipe; dilute the special floor heating solution into the hot water inlet pipe; ensure that the geothermal pipe is filled with water, close the cold water valve, and start the circulation pump for 30 minutes; open the cold water valve to clean the muddy water Flush the geothermal pipes with clean water until clean water flows out of the outlet pipe. Cleaning is completed.

Geothermal pipe maintenance method

1. Floor heating system is temporarily not used after installation. If the indoor temperature is lower than 5°C, the water in the system should be blown out with an air compressor to prevent the system from freezing.

2. The initial heating should be conducted under the guidance of the floor heating company's technical personnel. It is strictly prohibited to put it into use without debugging.

3, low temperature hot water floor heating system radiant heating temperature should use 35-50 °C, should not exceed 60 °C, heating system working pressure does not exceed 0.8MPa.

4. When the geothermal heating system is enabled in winter every year, it must be strictly in accordance with the prescribed heating program to gradually progress, and cannot be warmed up in one step.

5. The filter on the front end of the water separator can be cleaned before use every year to ensure the cleanliness of the water pipe and prevent the pipeline from being blocked. The specific methods are as follows: first, close the inlet and outlet valves of the connection pipe; then, open the filter and take out the filter And clean, check the filter for damage, clogging, if any damage should be replaced with the same specifications of the filter, according to the original can be installed.

6, floor heating system in the beginning of the water supply or use of the process, the pipeline may accumulate air, affect the heating effect, then you can open the manifold, the collector of the air valve, the gas discharge, the same method and traditional heating.

7. The floor of floor heating pipe laid under the ground is only about 3-4cm away from the floor. It is easy to injure the floor heating pipe by knocking or hitting the ground. Therefore, it is strictly forbidden to knock on the ground and hit the ground on the floor where the floor is laid. Sharp objects to prevent damage to the floor heating pipe. It is forbidden to bear more than 2 tons/m2 of load on the ground.

Editor's summary: How to clean the heating pipe and the maintenance method of the geothermal pipe are introduced here. I hope I can help you. For more information, please pay attention to this site.

Curtain installation method smoke machine cleaning building materials maintenance how to avoid decoration contract trap door maintenance

Track Light

LED ceiling track light with CRI 90 shows the true color of the object and gets a vivid lighting experience that is suitable for art studio lighting. Modern lighting fixture's direction can 350° horizontal and 90° vertical rotation so that the LED lighting can be easy to install and use. Wall track lighting fixtures ceiling spotlight uses die cast aluminium material with great heat dissipation. We promise a 3-year warranty, no worry about using in commercial lighting. Jiangmen Synno Co., Ltd is a high and new-tech enterprise. Our company specialized in LED green light source. And we are engaged in medium and high-end LED decorative lighting with a whole set of design and manufacture of lamps and lanterns, development of control system and engineering supporting service. Our company is devoted to provide customers with LED application products. Synno has got through ISO9001 quality system certification of SGS of Switzerland, CE certification of European Union, GS certification, ROHS certification and relevant domestic LED lamps and lanterns certification.