Vacuum oil filter normal maintenance

Always monitor the vacuum filter control panel filter alarm conditions and the pressure gauge indication. If the alarm sounds, the indicator light is on and it stops automatically, the filter has been contaminated and the filter element should be replaced.

Always monitor the differential pressure in the strainer and clean the filter when the pressure difference exceeds 0.15 MPa.

Frequently monitor the operation of the heaters on the instrument panel, the indicators, and the temperature indications.

Always check the vacuum oil filter vacuum and maintain the vacuum between -0.08 and 0.09 MPa.

After running for a period of time, samples were taken from the sampling valve of the machine to detect the content of moisture and mechanical impurities in the oil until the requirements were met.

Every 100 hours of operation should be checked: whether the vacuum system has a leak, and loosen the bolts again. The ultimate vacuum of the vacuum pump has reached the rated value. Whether the connector of the electrical component is loosened and fastened again.

Verify the accuracy of pressure gauges, vacuum gauges, and thermometers.

After the vacuum oil purifier is shut down, the oil and water in the system and equipment shall be drained. Especially in winter, be sure to clean the oil and water in the pipeline and vacuum pump to prevent freezing and squashing equipment.

Led Flood Light

WOSEN is a professional LED flood lights/solar flood lights/outdoor flood lights manufacturer/supplier in China, we have 30 years of OEM experience in outdoor floodlights, and have professional certification from international certification organizations , the floodlights produced meet the US and EU standards, and are the best choice for your flood lights supplier.