Fault Analysis of Taiyuan Elevator Inverter Maintenance

Taiyuan professional maintenance inverter, soft starter, PLC, instrumentation, touch screen, industrial control products, installation and commissioning inverter, three crystal inverter agent, Yingwei Teng inverter agent sales, Taiyuan professional maintenance Siemens inverter, ABB inverter Taiyuan professional level Maintenance, designated agent repair fixed points, a large number of stock, low maintenance costs, good quality.
Repairing a lot of inverters for elevators, I found that many faults are caused by the high temperature of the working environment, which makes the components easy to age. The elevator frequency converter is installed in the top control room of the building, often exposed to the sun in the summer, plus The heating of the inverter itself and the braking resistor makes the temperature in the electrical room very high, and the high working environment temperature will shorten the service life of the electronic components! The frequency converter is more obvious in this respect, so the elevator electrical room should pay attention to heat insulation in addition to ventilation problems in design, such as hollow bricks for walls and multi-layer design of the roof. If it can be equipped with air conditioner, the life of the inverter will be much longer. ! If the electric cabinet of the inverter is installed in Xiamen, if the internal temperature is high, the electric cabinet door should be opened. I have seen many manufacturers' electric cabinet design is too small! Just installed the inverter! And no cooling fan installed!
About the daily maintenance of the elevator inverter: Now the elevator is controlled by the inverter. When the inverter fails, it will cause inconvenience to many people, and it will also irritate the management personnel. If the inverter is usually maintained, Greatly reduce the failure rate of the inverter. After repairing a large number of elevator inverters, we should summarize several problems that should be paid attention to during normal maintenance: 1) The temperature of the elevator electrical room should not be too high, otherwise the inverter components are easy to age, preferably installed. Air conditioning, the effect is quite good! 2) Prevent rainwater from getting wet. Usually when the typhoon is being blown, the window door is blown by the wind and the inverter is drenched into the rain. 3) Lightning protection, this is related to the lightning protection facilities of the whole building or the whole community. The inverters that are struck by lightning are generally damaged seriously. 4) The cooling fan of the inverter should be cleaned regularly, and it should be replaced if it is loud or not running. 5) The abnormal sound of the elevator motor is usually caused by the inverter. If the three-phase current of the motor is unbalanced, it is best to repair it. If the inverter is completely out of order, the damage may be serious. If you don't have maintenance experience, don't repair it yourself. Many people make the inverter worse. ——An elevator repair company sent a Fuji VG5 inverter from Guangri Elevator to repair it. It has been repaired twice. It took a few days to burn the module, and the loss was heavy! After inspection, it is because the latex glue is applied to the bottom plate of the module with the heat-dissipating glue, and the module is poorly cooled and burned. Http://news.chinawj.com.cn Fault Analysis of Taiyuan Elevator Inverter Maintenance Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn Fault Analysis of Taiyuan Elevator Inverter Maintenance

Brushless Tools 21V

Brushless Tools,Cordless 21V Tools,Electric Grinder Tool,Angle Grinder Machine

ZHENGYANG TECHNOLOGY CO.,LTD , https://www.supraone.com

Posted on