The principle and composition of carbon fiber electric floor heating

The working principle of carbon fiber electric floor heating is to generate "Brown motion" through the carbon molecular group under the excitation of electricity, and the thermal energy is generated by the collision and friction between carbon molecules, generating a large amount of infrared radiation, and the conversion rate of electric energy and thermal energy is up to 98% or more. The working principle of carbon fiber electric floor heating is to generate "Brown motion" through the carbon molecular group under the excitation of electricity, and the thermal energy is generated by the collision and friction between carbon molecules, generating a large amount of infrared radiation, and the conversion rate of electric energy and thermal energy is up to 98% or more.


The carbon fiber floor heating system consists of four subsystems: heating system, insulation system, temperature control system, and circuit system.

The main core heat-generating component of the "heating system" is a carbon fiber filament heating element;

The main material of the "insulation system" is polystyrene extruded board. The function of the insulation system is to prevent the loss of heat generated by the carbon fiber electric floor heating to the floor direction and to force the heat to be transmitted to the room;

The main component of the "temperature control system" is the electric heating thermostat. The thermostat controls the heat provided by the carbon fiber electric floor heating by sensing the change in the ambient temperature of the heating room. Reasonable heating temperature setting can greatly improve the effective working efficiency of the system and reduce energy consumption;

The "circuit system" consists of installation materials such as power lines.

The article was published at: http://://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn

GET-S intelligent economy type PCR Machine adopts 6 American Marlow standard semiconductor cooling chips, the maximum temperature changing rate is greater than 4.5 degrees per second, and the number of cycles is greater than 200 thousand times. GET-S Series thermalcycler integrates a variety of advanced technology in one: WINCE operating system, color full touch screen, a variety of replaceable modules, computer online functions, printing functions, large data storage and expansion functions, all of which will improve the function of qualitative PCR products to the extreme, powerful functions will meet the needs of higher requirements of the experiment.


Characteristic

  1.  6 long life Peltier modules, which consist of 3 sets of loops, can independently control 3 temperature zones.
  2.  the engineering reinforced aluminum module processed by anodizing technology not only keeps fast thermal conductivity but also has enough corrosion resistance.
  3.  fast temperature rise and fall rate, the fastest temperature rise and fall rate of 4.5 /s, saving valuable experimental time.
  4. stepless adjustable hot cover can be used to test tubes at different heights, and can be positioned at any angle after opening.
  5. The friendly Windows interface, color touch screen control, high clear TFT display (8 inches, 800 x 600 pixels, 16 color), graphical menu navigation interface, operation is extremely simple;
  6. built in 11 standard program file templates to quickly edit the required files;
  7. the program adopts folder management and can build its own directory.
  8. real-time display program progress and remaining time, support PCR instrument running intermediate programming;
  9. the fast incubation function of one button can meet the experimental needs of denaturation, enzyme digestion / enzyme linked, ELISA and so on.
  10. large data storage and maximum storage of 10 thousand files in the machine.
  11. hot cover temperature and hot cover working mode can be set up to meet different experimental needs.
  12. automatic power failure protection, automatic recovery of power supply after the completion of the unfinished cycle, ensure the whole process of safe operation.
  13. the GLP experiment report records the operation information of each step of the program, and provides accurate data support for the analysis of the experimental results.
  14. User login management, three level permissions, password protection function, to ensure data security;
  15. USB interface, supporting U data / PCR data, or using USB mouse to control PCR tester.
  16. Support U disk and LAN update software;
  17. through the network connection, one PCR can be controlled simultaneously.
  18. optional micro wireless Bluetooth printer, easy and accurate record of the experimental program information.
  19. support the end of the experiment program sending mail reminder function.


Capacity: 96*0.2ml, 96*0.2ml+ 77*0.5ml, 60*0.5ml, 384well 

Temperature range: 0-100C


Gradient PCR machine

PCR thermalcycler




GET-S Series PCR Thermal Cycler

GET-S Series PCR Machine,GET-S Series Thermal Cycler/ PCR Machine,GET-S Series PCR Thermal Cycler Machine,GET-S Series PCR Thermal Cycler,Thermal Cycler PCR

Zhengzhou mingyi instrument equipment co.,ltd , https://www.mingyint.com

Posted on