- Hardness indicates the ability of a material to resist the pressing of a hard object into its surface. It is one of the important performance indicators of metallic materials. Generally, the higher the hardness, the better the wear resistance. Commonly used hardness indexes are Brinell hardness, Rockwell hardness and Vickers hardness.
1. Brinell hardness (HB)
A certain size (usually 3000kg) of a hardened steel ball of a certain size (typically 10mm in diameter) is pressed into the surface of the material for a period of time. After the load is removed, the ratio of the load to the area of ​​the indentation is the Brinell hardness value ( HB), the unit is kg/mm2 (N/mm2).
2. Rockwell hardness (HR)
When HB>450 or the sample is too small, the Brinell hardness test cannot be used instead of the Rockwell hardness measurement. It uses a diamond cone with a apex angle of 120° or a steel ball with a diameter of 1.59 and 3.18 mm, and is pressed into the surface of the material to be tested under a certain load, and the hardness of the material is determined from the depth of the indentation. According to the hardness of the test material, it is represented by three different scales:
HRA: It is a hardness obtained by using a 60kg load and a diamond cone indenter for materials with extremely high hardness (such as cemented carbide).
HRB: It is a hardened steel ball with a load of 100kg and a diameter of 1.58mm. The hardness is used for materials with lower hardness (such as annealed steel, cast iron, etc.).
HRC: is the hardness obtained by using a 150kg load and a diamond cone indenter for materials with high hardness (such as hardened steel).
3 Vickers hardness (HV)
The surface of the material is pressed into the surface of the material with a load of 120 kg or less and a diamond square cone presser with a apex angle of 136°. The surface area of ​​the material indentation pit is divided by the load value, which is the Vickers hardness value (HV).
As can be seen from the above, Vickers hardness is one of the surface hardnesses. It has a conversion relationship with other hardness units.
Hardness refers to the surface hardness, and there is no hardness requirement inside the material. Only mechanical properties (tensile strength, yield strength and impact toughness).
Why is there no surface hardness in GB/T 3098.1-2000? Does 5.6 not indicate the surface hardness? The surface hardness should not be 30 Vickers hardness (about 3 HRC) higher than the core hardness. The surface of 10.9 level The hardness should not be greater than 390HV0.3. As for the lack of surface hardness, it is a low performance grade, such as 3.6 4.6 4.8 5.6 5.8 6.8, because there is no heat treatment, so there is no requirement, because the hardness of his surface is mainly cold heading or baking turning. The hardness generated by the post stress.
When testing the hardness of the bolt, there is no heat-treated bolt. It is only necessary to make the surface hardness within the acceptable range. If it is a heat-treated bolt, it should be hardened on the surface without cutting a diameter. The hardness test is 1/2R on the surface. Where the hardness meets the standard.
It has a core with a surface, and the surface refers to the hardness after using the Vickers or the surface Rockwell after removing the surface rust, etc., and the core is to be removed from the surface and the core after removing the 1/2 diameter portion of the portion. 2 places hardness, the difference between the two hardness can not exceed 30 HV, the surface is higher than 30HV indicating that the surface is carburized, it is not allowed, if the surface is lower than 30HV, the surface decarburization is not allowed. Look carefully at this 3098.
LEDER technology`s street light is built and integrated with World's 1st AI as a software based version for a wide range of commercial, industrial and residential lighting applications. This high quality and very durable light is completely self-contained.This LED street light provides users one step Power-ON for Dusk to Dawn or Dark Sky City illumination all night long.
Build-in light-sensor, this solar gutter LED street lights with clips can auto on at night and off during the day. Waterproof rating and durable construction resistant for all kinds of weather, there is no worry about being damaged by the rain or snow. To be fully charged in only 6-7 hours, providing a long working time about 12-18 hours in bright mode. Easy to install.
Features:
• Artificial Intelligence
• Outdoor use
• Group and control multiple lights with the smart life app
• Energy saving save electricity
• Environmental Care
• Color temperature :3000k-6000K
• Safe and beautiful
• Type of protection: IP20 /IP65 (Some models)
• Warranty:3 - 5 years
This LED street light is perfect for outdoor use, such as a walkway, fence, garden, path, patio, gutter, and so on. Replace your old outdoor parking lot lights with a high efficiency LED street light. Save money and replace bulbs less often with a 50,000 hour rated LED. The fixture is also ideal for new installations. Light up an area of your parking lot, walkways, and sports court for safety and aesthetics.
We have rich production experience in lighting. Except LED Street Light, we also offered other product in Outdoor Lighting ,such as LED Flood Light , LED Inground Light, LED Spike Light ,LED Bollard Light ,LED Wall Washer,Outdoor Wall Light & step light as so on .
Solar Street Light,Solar Street Lamp,Solar LED Street Light,Solar Powered Street Lights
JIANGMEN LEDERLIGHT LIGHTING Co.,LTD , https://www.ledpolelights.com